F56/P10A VA Flow meter
Variable Flow Meter
Transmitter with Local LCD Indicator is designed on the basis of PCB multifunction flow, the signal measured is converted to flow value by magnetic coupling. The value is both shown by the pointer on the
scale plate and on LCD.
Overview
BABI F56/P10A VA Flow Meter เครื่องวัดอัตราการไหลแบบ Variable Area พร้อมจอแสดงผล เหมาะสำหรับงานวัดและควบคุมการไหลในโรงงาน
Features
- Made of stainless steel stainless steel by stamping forming.
- Local instantaneous flow indicated by mechanical pointer.
- Instantaneous flow, accumulated flow and percentile flow indicated on LCD.
- Two wire system 4-20mA, Hart Protocol Digital communication.
- Parameter setting by full function key, HART communicator and PC.
- IS (intrinsically safe)/ Flameproof function.
- Electrical connection part connected by M12 plug-and-play aviation plug.
P10 Indicator:
- Modularization design Exi, Exd explosion protection housing
- 2-wire electrical signal output (4-20)mA/HART
- Optional limit alarm
Specifications
GENERAL SPECIFICATION
Technical Data
| Type | F56 | |||
| Medium | Liquids, gases, vapors | |||
| Rang(conversion to 100% value of reference fluid ) | Water : 20℃ | (10-300000)L/h , Special order on request: | ||
| Air : 0.1013MPa, 20℃ | (0.7-3000)Nm3/h, Special order on request: | |||
| The turn-down ratio | 10 : 1 | |||
| Accuracy class | Mechanical indicator | 1.0, 1.5, 2.0, 2.5 | ||
| Mechanical indicator with LCD(battery powered, service life: 2 years) | 1.0, 1.5, 2.0, 2.5 | |||
| Mechanical indicator with two-wire signal output (4-20)mA/hart communication protocol | 1.0, 1.5, 2.0, 2.5 | |||
| Medium temperature | Machinery indicator with LCD(battery powered, service life: 2 years) | -80℃~+300℃ (PTFE:0~80℃)
High temperature 400℃ |
||
| Mechanical indicator(battery powered, service life : 2 years) | -40℃~+120℃ (PTFE:0~80℃)
High temperature 400℃ |
|||
| Mechanical indicator with two-wire signal output (4-20)mA/hart communication protocol | -40℃~+120℃ (PTFE:0~80℃)
High temperature 400℃ |
|||
| Ambient temperature | Mechanical indicator | -40℃~+120℃ | ||
| Mechanical indicator with LCD(battery powered, service life: 2 years) | -20℃~+60℃ | |||
| Mechanical indicator with two-wire signal output (4-20)mA/hart communication | -20℃~+60℃ | |||
| Viscosity of fluid | DN15: F15.00~F15.03 η<5 mPa.s, F15.04~15.30 η<30 mPa.s; DN25: η<250 mPa.s; DN50~250: η<300 mPa.s | |||
| Nominal pressure | DN15~DN50 | 4.0MPa(Max DN15: 42MPa, DN25: 42MPa, DN50: 32MPa) | ||
| DN80~DN250 | 1.6MPa(Max DN80: 10MPa, DN100: 6.4MPa, DN125: 4.0MPa,
DN150: 4.0MPa, DN200: 2.5MPa, DN250: 2.5Mpa) |
|||
| Process connection | Flange connection, Standard: DIN2501, ANSI, JIS(select Chinese standard freely, priority select DIN) | |||
| Hygiene clamp, screw joint are selected in the order | ||||
| Electrical connection | M20×1.5 1/2″G 1/2″NPT 3/4″G 3/4″NPT | |||
| Installation | Vertical installataion(bottom in up out and up in bottom out, Horizontal installataion(left in right out and right in left out)
bottom in side out, side in side out |
|||
| Straight unimpeded inlet run | ≥ 5D | |||
| Straight unimpeded outlet run | ≥ 250 mm | |||
| Degree of protection | IP67(Others need specify in the order) | |||
| Ex marking | EEx ia II CT5 | |||
| EEx d II CT6 | ||||
| Ex electrical data | Ui = 28V Ii = 93mA Pi = 0.65W Ci ≤ 5nF Li =0mH | |||
| Safety barrier data | Uo ≤ 28V Io ≤ 93mA Po ≤ 0.65W Co ≥ Ci+Cc Lo ≥ Li+Lc | |||
| Carried Standard | JB/T 6844-93 | |||
Downloads
สนใจสินค้า หรือขอใบเสนอราคา
แจ้งรุ่นสินค้าและรายละเอียดการใช้งาน เพื่อให้ทีมงานช่วยเลือก Flow Meter ที่เหมาะสม
F56/P10A VA Flow meter
Variable Flow Meter
Transmitter with Local LCD Indicator is designed on the basis of PCB multifunction flow, the signal measured is converted to flow value by magnetic coupling. The value is both shown by the pointer on the
scale plate and on LCD.
Related products
-
Coriolis flow meter
MS-25
-
Differential Pressure
ISB/2
-
Coriolis flow meter
OPTIMASS 7010
-
Differential Pressure
MEF/2