INDUSTRIAL FLOW METER

VA45

Variable area flowmeter for low pressure gas applications

  • Glass tube with easy-to-read scale
  • For use in gas supply lines of furnaces, protective gas or heating systems
  • Flange: DN15…40 / ½…1½”; also NPT, G, hose connection
  • -20…+100°C / -4…+212°F; max. 1 barg / 14.5 psig
หมวดหมู่: , ,
แบรนด์: KROHNE

Overview

The VA45 is a glass tube variable area (VA) flow meter for flow measurement of gases at low operating pressures (<1 barg /<14.5 psig). The device is ideally suited for use in gas supply lines of industrial ovens, forges and furnaces or protective gas and heating systems (with process temperatures up to +100°C / +212°F).

The VA 45 operates without auxiliary power supply. The glass measuring cone, protected by a metal sleeve with a viewing glass, makes it easy to directly read the flow and to observe the medium. The standard version is available with flange, thread or hose connections.

Features

  • Simple, low-cost measuring principle without auxiliary power
  • For direct reading of the flow and observation of the medium
  • Full scale value for gases: 2300…75,000 l/h / 85…2790 SCFH
  • Maximum measuring error: ±2.5% (acc. to VDI/VDE 3513-2) or ±2% of full scale
  • Turndown ratio: 10:1

Applications

Machinery and apparatus (OEM industry)

  • Air supply to furnaces etc.
  • Dosing of protective gases

Specifications

General information

Product type Flowmeter
Product family name VA
Product positioning For low pressure gas applications
Measurement principle Variable area float
Measured media Gases

Operating conditions

Process pressure max. 1 barg/
14.50 psig
Process temperature 0…+100°C/
+32…+212°F

Materials

Measuring tube Borosilicate glass
Gaskets Ethylene propylene diene monomer (EPDM), Perfluoroelastomer rubber (FFKM), Fluoroelastomer rubber (FPM), Nitrile butadiene rubber (NBR)
Process connection Austenitic stainless steel (1.4404/316L), Polyvinylidene fluoride (PVDF), Chromised steel

Process connections

Flange connections EN (1092-1): DN15…40
ASME (B 16.5): ½… 1½”
Thread connections Female:
G½, G¾, G1, G1½
½ NPT, ¾ NPT, 1 NPT, 1½ NPT
Other connections Hose: DN15, DN25, DN40

Downloads

สนใจสินค้า หรือขอใบเสนอราคา

แจ้งรุ่นสินค้าและรายละเอียดการใช้งาน เพื่อให้ทีมงานช่วยเลือก Flow Meter ที่เหมาะสม

, ,

VA45

Variable area flowmeter for low pressure gas applications

  • Glass tube with easy-to-read scale
  • For use in gas supply lines of furnaces, protective gas or heating systems
  • Flange: DN15…40 / ½…1½”; also NPT, G, hose connection
  • -20…+100°C / -4…+212°F; max. 1 barg / 14.5 psig
Categories: , , Brand:
Scroll to Top